DIAGNOSIS START CONDITION:

Ignition voltage is 10 V to 16 V.

DTC DETECTING CONDITION:

Curtain airbag sensor RH unit internal malfunction

If DTC B1630 is displayed, the circuit within the curtain airbag sensor RH is faulty.

Replace the curtain airbag sensor RH. Curtain Airbag Sensor

Dtc b1632 curtain airbag sensor rh lost communication
DIAGNOSIS START CONDITION:Ignition voltage is 10 V to 16 V.DTC DETECTING CONDITION:Curtain airbag sensor RH communication error (open/short circuit or connector connection failure between airbag CM an ...

Dtc b1628 side airbag sensor lh initialization error
DIAGNOSIS START CONDITION:Ignition voltage is 10 V to 16 V.DTC DETECTING CONDITION:Side airbag sensor LH unit malfunction (sensor type abnormal, sensor unit initialization error)CAUTION:Before perform ...

Other materials:

Registration body integrated unit operation
1. CONFIRM CURRENT SETTING1. On «Start» display, select «Diagnosis».2. On «Vehicle selection» display, input the target vehicle information and select «Confirmed».3. On «Main Menu» display, select «Each System».4. On «Select System» display, select «Body Control» and then select «En ...