DTC DETECTING CONDITION: Immediately at fault recognition CAUTION: After servicing or replacing faulty parts, perform Clear Memory Mode Clear Memory Mode > OPERATION, and Inspection Mode Inspection Mode > PROCEDURE. WIRING DIAGRAM: • Engine Electrical System ENGINE TYPE FB (WITHOUT PUSH BUTTON START) Engine Electrical System > WIRING DIAGRAM • Engine Electrical System ENGINE TYPE FB (WITH PUSH BUTTON START) Engine Electrical System > WIRING DIAGRAM STEP | CHECK | YES | NO | 1.CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY RH CONNECTOR. 1) Turn the ignition switch to OFF. 2) Disconnect the connectors from the ECM and tumble generator valve assembly RH. 3) Measure the resistance of harness between ECM connector and tumble generator valve assembly RH connector. Connector & terminal (E158) No. 52 — (E55) No. 5: (E158) No. 13 — (E55) No. 4: | Is the resistance less than 1 -- | Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2008 TGV CONTROL CIRCUIT/OPEN BANK 1 | Repair the harness and connector. NOTE: In this case, repair the following item: • Open circuit in harness between ECM connector and tumble generator valve assembly RH connector • Poor contact of coupling connector | 2.CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ASSEMBLY RH CONNECTOR. Measure the resistance between ECM connector and chassis ground. Connector & terminal (E158) No. 52 — Chassis ground: (E158) No. 13 — Chassis ground: | Is the resistance 1 M- or more- | Diagnostic Procedure with Diagnostic Trouble Code (DTC) > DTC P2008 TGV CONTROL CIRCUIT/OPEN BANK 1 | Repair the short circuit to ground in harness between ECM connector and tumble generator valve assembly RH connector. | 3.CHECK FOR POOR CONTACT. Check for poor contact of tumble generator valve assembly RH connector. | Is there poor contact of the tumble generator valve assembly RH connector- | Repair the poor contact of tumble generator valve assembly RH connector. | Replace the tumble generator valve assembly RH. Tumble Generator Valve |
1. OUTLINE OF DIAGNOSIS Detect the open or short circuit of tumble generator valve motor. Judge as NG when the open signal is sent from IC after tumble generator valve driving IC diagnosis. 2. COMPONENT DESCRIPTION (1) | Engine control module (ECM) | (2) | Tumble generator valve | | |
3. EXECUTION CONDITION Secondary Parameters | Execution condition | Battery voltage | ≥ 10.9 V | Tumble generator valve drive duty | ≤ 79.17% |
4. GENERAL DRIVING CYCLE Perform the diagnosis continuously after the enable conditions have been established. 5. DIAGNOSTIC METHOD If the duration of time while the following conditions are met is longer than the time indicated, judge as NG. Judgment ValueMalfunction Criteria | Threshold Value | Output voltage | > Battery voltage - 0.55 | Time Needed for Diagnosis: 96 ms - 20 time(s) Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs. |