Subaru Legacy BN/BS (2015-2019) Service Manual: Inspection
1. Check the continuity between the connectors. Terminal No. | Inspection conditions | Specification | 4 (COM) — 5 (GND) | Always | Continuity exists | 7 (SSW1) — 5 (GND) | Push button ignition switch released > pressed | Continuity exists | 2 (SSW2) — 5 (GND) | Push button ignition switch released > pressed | Continuity exists |
2. Check the push button ignition switch operation when battery voltage is applied between the connectors. Terminal No. | Inspection conditions | Specification | 11 (SWIL) — 5 (GND) | Connect battery to the terminals | Goes off > Red switch illumination light | 12 (INDS) — 5 (GND) | Turns off > Switch indicator lights in green | 13 (INDW) — 5 (GND) | Turns off > Switch indicator lights in orange |
3. Replace the push button ignition switch if the inspection result is not within the standard value. |
1. Disconnect the ground terminal from battery sensor. NOTE2. Remove the cover assembly - instrument panel LWR driver. Instrument Panel Lower Cover > REMOVAL3. Remove the visor assembly - lower.(1) ...
1. Install the push button ignition switch to the visor assembly - lower.2. Install the visor assembly - lower.3. Install the cover assembly - instrument panel LWR driver.4. Connect the ground termina ...
Other materials:
Engine lubrication system trouble in general inspection
Before performing diagnostics, make sure that the engine oil level is correct and no oil leakage exists.TroublePossible causeCorrective actionWarning light remains ON.a. Oil pressure switch failure Cracked diaphragm or oil leakage within switchReplace. Broken spring or seized contactsReplace.b ...