1. BASIC DIAGNOSTIC PROCEDURE
NOTE: If the horn sounds when the security is turned on (monitor condition) using the keyless transmitter or access key, check the function setting of the body integrated unit. As a cause, it is possible that the impact sensor present (ON) / not present (OFF) setting is set to ON in the customization function though there is no impact sensor. User Customizing 2. CHECK SECURITY SYSTEM CONDITION MEMORY 1. Pull out the key from the ignition switch, or turn the ignition switch to OFF. 2. Close all the doors, trunk lid or rear gate. 3. Open the front hood. 4. Press the LOCK button of the keyless transmitter or access key. NOTE: Wait until the security indicator light blinks twice within 0.5 seconds at 2 second intervals. If the 30 second monitoring lag has been set, wait for 30 seconds. 5. Disconnect the ground terminal from battery sensor. NOTE 6. Connect the ground terminal to battery sensor. NOTE 7. Check that the security indicator light blinks twice within 0.5 seconds at 2 second intervals. When it does not blink, replace the body integrated unit. 3. SECURITY SYSTEM ON/OFF SETTING NOTE: It can be set by «Security Alarm Setup» in unit customizing using Subaru Select Monitor. For detailed operation procedures, refer to “Application help”. 1. Close all doors, trunk lid or rear gate, and sit down on the driver seat. Press the UNLOCK button of the keyless transmitter or access key. 2. Turn the ignition switch to ON. 3. Press the central door unlock switch and open the driver’s door simultaneously. (Keep the central door unlock switch pressed down.) 4. When the condition in step 3) continues for 10 seconds, the system switches to a mode reverse to the current mode.
4. CHECK DOOR SWITCH For operation procedure, refer to “CHECK DOOR SWITCH” of “Keyless Entry System”. Keyless Entry System > INSPECTION 5. CHECK SECURITY INDICATOR LIGHT CIRCUIT For operation procedures, refer to “CHECK SECURITY INDICATOR LIGHT CIRCUIT” of “IMMOBILIZER (DIAGNOSTICS)” section. Diagnostics Chart for Security Indicator Light > INSPECTION 6. CHECK HORN
7. CHECK HAZARD LIGHT OPERATION For operation procedure, refer to “CHECK HAZARD LIGHT OPERATION” of “Keyless Entry System”. Keyless Entry System > INSPECTION 8. CHECK IGNITION SWITCH CIRCUIT
|
Dtc b1414 immobilizer control module non-volatile memory
DIAGNOSIS START CONDITION:• Battery voltage is 10 V or more.• The remote engine starter was not used to start the engine.DTC DETECTING CONDITION:• Defective immobilizer CM• Failed to access the ROM in immobilizer CM.TROUBLE SYMPTOM:Engine will not start.CAUTION:When the immob ...