1. BASIC DIAGNOSTIC PROCEDURE

STEPCHECKYESNO

1.INITIAL CHECK.

Check the keyless entry system or keyless access system operation.

Does the keyless entry system or keyless access system operate normally-

Security System > INSPECTION

Check the keyless entry system or keyless access system.

Keyless entry system: Keyless Entry System > INSPECTION

Keyless access system: General Description > CAUTION

2.CHECK SECURITY ON/OFF SETTING.

1) Remove the key from ignition switch or turn the ignition switch to OFF, and close all doors.

2) Check the status of security indicator light.

3) Press the LOCK button of the keyless transmitter or access key.

4) Check the security indicator light blinking patterns.

Is the security indicator light blinking patterns as follows-
• Before pressing the LOCK button:
Blinks once every three seconds.
• After pressing the LOCK button:
When monitoring lag is set to 0 seconds: Blinks twice every 0.5 seconds at 2 second intervals.
When monitoring lag is set to 30 seconds: Blinks once every 0.4 seconds continuously for 30 seconds, then blinks twice every 0.5 seconds at 2 second intervals.

Security System > INSPECTION

Security System > INSPECTION

3.CHANGE SETTING OF SECURITY SYSTEM.

Change the setting of security system to ON using Subaru Select Monitor. Security System > INSPECTION

Is setting change completed correctly-

Security System > INSPECTION

Replace the body integrated unit. Body Integrated Unit

4.CHECK SECURITY SYSTEM OPERATION.

1) Remove the key from ignition switch or turn the ignition switch to OFF, and close all doors.

2) Press the LOCK button on the keyless transmitter or access key, then wait for 30 seconds.

3) Check the security indicator light blinking patterns.

Does the security indicator light blink twice within 0.5 seconds in 2 second intervals-

Security System > INSPECTION

Check the security indicator light. Security System > INSPECTION

5.CHECK SECURITY ALARM OPERATION.

1) Operate the driver’s door lock switch to the UNLOCK side.

2) Open any door, trunk lid or rear gate.

Does the security alarm operate when opening any door, trunk lid, or rear gate-

Security System > INSPECTION

Check the following parts. Keyless Entry System > INSPECTION

Door switches

Trunk lid latch switch

Rear gate latch switch

6.CHECK SECURITY ALARM OPERATION.

Check the security alarm operation status.

During the operation, does the horn keep sounding and the hazard light blink-

Security System > INSPECTION

Check the following parts. Keyless Entry System > INSPECTION

Horn: Security System > INSPECTION

Hazard light: Security System > INSPECTION

7.CHECK SECURITY ALARM CANCEL OPERATION.

Press any button of the transmitter or access key while the security alarm is operating.

Do the horn sound and the blinking of the hazard light stop-

Security System > INSPECTION

Replace the body integrated unit. Body Integrated Unit

8.CHECK IMPACT SENSOR (DEALER OPTION).

Check the sensibility of impact sensor. Impact Sensor > ADJUSTMENT

* For models not equipped: Security System > INSPECTION

Is the sensibility set properly-

Security System > INSPECTION

Adjust the sensitivity. Impact Sensor > ADJUSTMENT

9.CHECK SECURITY SYSTEM CONDITION MEMORY.

1) Remove the key from ignition switch or turn the ignition switch to OFF, and close all doors.

2) Open the front hood.

3) Press the LOCK button on the keyless transmitter or access key, then wait for 30 seconds.

4) Disconnect the ground terminal from battery sensor. NOTE

5) Connect the ground terminal to battery sensor. NOTE

6) Check the status of security indicator light.

Does the security indicator light blinks twice within 0.5 seconds at 2 second intervals-

Security System > INSPECTION

Replace the body integrated unit. Body Integrated Unit

10.CHECK SECURITY SYSTEM MANUAL ON/OFF SETTING.

1) Press the UNLOCK button of the keyless transmitter or access key.

2) Change the setting of security system. Security System > INSPECTION

Is setting change completed correctly-

Restore the security system settings to those before the diagnosis and finish the diagnosis.

Check the following parts.

Ignition switch circuit: Ignition Key Lock > INSPECTION

Door lock switch circuit: Door Lock Control System > INSPECTION

NOTE:

If the horn sounds when the security is turned on (monitor condition) using the keyless transmitter or access key, check the function setting of the body integrated unit. As a cause, it is possible that the impact sensor present (ON) / not present (OFF) setting is set to ON in the customization function though there is no impact sensor. User Customizing

2. CHECK SECURITY SYSTEM CONDITION MEMORY

1. Pull out the key from the ignition switch, or turn the ignition switch to OFF.

2. Close all the doors, trunk lid or rear gate.

3. Open the front hood.

4. Press the LOCK button of the keyless transmitter or access key.

NOTE:

Wait until the security indicator light blinks twice within 0.5 seconds at 2 second intervals.

If the 30 second monitoring lag has been set, wait for 30 seconds.

5. Disconnect the ground terminal from battery sensor. NOTE

6. Connect the ground terminal to battery sensor. NOTE

7. Check that the security indicator light blinks twice within 0.5 seconds at 2 second intervals. When it does not blink, replace the body integrated unit.

3. SECURITY SYSTEM ON/OFF SETTING

NOTE:

It can be set by «Security Alarm Setup» in unit customizing using Subaru Select Monitor.

For detailed operation procedures, refer to “Application help”.

1. Close all doors, trunk lid or rear gate, and sit down on the driver seat. Press the UNLOCK button of the keyless transmitter or access key.

2. Turn the ignition switch to ON.

3. Press the central door unlock switch and open the driver’s door simultaneously. (Keep the central door unlock switch pressed down.)

4. When the condition in step 3) continues for 10 seconds, the system switches to a mode reverse to the current mode.

Setting

Horn activation

Meter display

ON > OFF

Twice

[AL_OF]

OFF > ON

Once

[AL_ON]

4. CHECK DOOR SWITCH

For operation procedure, refer to “CHECK DOOR SWITCH” of “Keyless Entry System”. Keyless Entry System > INSPECTION

5. CHECK SECURITY INDICATOR LIGHT CIRCUIT

For operation procedures, refer to “CHECK SECURITY INDICATOR LIGHT CIRCUIT” of “IMMOBILIZER (DIAGNOSTICS)” section. Diagnostics Chart for Security Indicator Light > INSPECTION

6. CHECK HORN

STEPCHECKYESNO

1.CHECK HORN OPERATION.

Check the horn sounds when the horn switch is pushed.

Does the horn sound-

Security System > INSPECTION

Check the horn circuit.

2.CHECK BODY INTEGRATED UNIT.

Select and perform the «Horn Output» using Subaru Select Monitor.

NOTE:

For detailed operation procedures, refer to “Application help”.

Does the horn sound-

Horn circuit is OK.

Security System > INSPECTION

3.CHECK HORN RELAY CIRCUIT.

1) Turn the ignition switch to OFF.

2) Disconnect the connector of body integrated unit.

3) Remove the horn relay.

4) Check the harness between body integrated unit and horn relay.

Connector & terminal

(B281) No. 20 — Horn relay No. 4:

Is harness normal-

Check body integrated unit. Basic Diagnostic Procedure

Repair or replace the harness.

7. CHECK HAZARD LIGHT OPERATION

For operation procedure, refer to “CHECK HAZARD LIGHT OPERATION” of “Keyless Entry System”. Keyless Entry System > INSPECTION

8. CHECK IGNITION SWITCH CIRCUIT

STEPCHECKYESNO

1.CHECK DATA MONITOR.

Display the data of «BATT voltage» and «IG power supply voltage» using the Subaru Select Monitor.

NOTE:

For detailed operation procedures, refer to “Application help”.

Does the «IG power supply voltage» indicate 0 V when the ignition switch is OFF, and fall within a range of ±1 V from the «BATT voltage» when the ignition switch is ON-

The ignition switch input circuit is OK.

Security System > INSPECTION

2.CHECK IGNITION SWITCH CIRCUIT.

1) Turn the ignition switch to OFF.

2) Disconnect the connector of body integrated unit.

3) Turn the ignition switch to ON.

4) Measure the voltage between the body integrated unit connector and chassis ground.

Connector & terminal

(i84) No. 10 (+) — Chassis ground (−):

Is the voltage 10 V or more-

Check body integrated unit. Basic Diagnostic Procedure

Check the harness for open or short circuit between body integrated unit and fuse.

Electrical specification
Refer to “Control Module I/O Signal” of “BODY CONTROL SYSTEM (DIAGNOSTICS)” section. Control Module I/O Signal > ELECTRICAL SPECIFICATION ...

Steering lock cm
...

Other materials:

Dtc b1414 immobilizer control module non-volatile memory
DIAGNOSIS START CONDITION:• Battery voltage is 10 V or more.• The remote engine starter was not used to start the engine.DTC DETECTING CONDITION:• Defective immobilizer CM• Failed to access the ROM in immobilizer CM.TROUBLE SYMPTOM:Engine will not start.CAUTION:When the immob ...