Honda Civic manuals

Subaru Legacy BN/BS (2015-2019) Service Manual: Intake (induction)(h6do)

Installation
The resonator chamber and air cleaner case are integrated into one unit; therefore, refer to “Air Cleaner Case” for installation procedure. Air Cleaner Case > INSTALLATION ...

Air cleaner case
...

Other materials:

Inspection
1. Measure the resistance between connector terminals.Preparation tool:Circuit testerTerminal No.Inspection conditionsStandard1 — 22 — 3Always1.82±0.07 -2. Replace the resistor assembly - daytime running light if the inspection result is not within the standard. ...